Tapo C530WS_V2_User Guide

1The Tapo S110E relay module connects via Wi-Fi and Bluetooth, operating in dry or wet contact modes based on wiring. 

*AC stands for alternating current and DC stands for direct current. 
Wiring Instructions
• Wet Contact Mode (Figure 1): Use the short wire provided to connect the "I" terminal to the "W" terminal.
• Dry Contact Mode (On/Off Mode)  (Figure 2): Connect the “O” terminal and the “I” terminal to the load circuit. Connect the L (DC-) and N (DC+) terminals to the input of the power supply.
• Dry Contact Mode (Pulse Mode)  (Figure 3): The switch module sends a short pulse signal through the “I” and “O” terminals.
Note
• Both push button switches and rocker switches are supported. Select the appropriate switch type when configuring the app.
• The two long wires provided are only for external switches. 
• You can use either AC or DC, not both.  For DC, verify correct polarity and voltage.
• Please follow the step-by-step wiring instructions in the Tapo app to complete the wiring.

Set Up

1. Get the Tapo app from the App Store or Google Play, and log in.

2. Tap the    +    button in the app and select Add Device. Follow the app instructions to complete the setup.

  • Via Tapo

           Go to Me > Third-Party Services to link Tapo to third-party services. 

  • Via Matter

            Use any smart home app that supports Matter to integrate the 

Operation Temperature: 0°C~35°C
Dimensions: 44.7 × 33.9 × 16.1 mm

English: Safety Information
Before installing, servicing or removing the switch module, read and follow all safety precautions including the following:
• Follow all national and local safety regulations and practices. If you are uncertain or uncomfortable when performing the installation, consult a qualified electrician.
• CAUTION – Risk of Electric Shock – An all-pole disconnect device may be required to de-energize the equipment before servicing. A circuit breaker which disconnects the Line and Neutral conductor simultaneously is suitable. Ensure power is off at the circuit breaker before removing or installing any switch module. Use a non-contact voltage tester to ensure the power is off.